Over Current (Trip detection) Error
Over current error codes by model:
9x Operation & 4x Timer:
RL2 series, RLS3 series, RLS2 series, RLB/RLXB series, RLF series, RLF1 series, LUAS1 series, LMAS series, LZBS series, LZAS series, LPAS series, RGLX series, RLE series
5x Operation & 3x Timer:
RLS series, RLXS series, CQ series, RQ series, R2 series, RL series, RML series, RMLQ series, CLX series, CLX1 series, RLX series, RLXQ series, CL1 series, CL series, RLQ series
2 flashes on Power Mode LED, Solid Error LED, 9 flashes on L1, 4 flashes on L2, solid L6 LED:
AOU30RLXEH
9 flashes on LED A, 4 flashes on LED B & solid LED F:
AOU36RLXFZH & AOU45RLXFZ
Continuous Operation flash & 11x Timer flash:
ABU18RULX, ABU24RULX & ABU36RSLX
E941:
AOU48RLXFZ & AOU48RLXFZ1
51 / 12 Wired remote:
UTY-RNBYU, UTY-RNNUM, UTY-RVNUM, UTY-RSNUM, & UTY-RNRUZ series, UTY-RSRY, UTY-RHRY
Over Current Error (CT Error) Troubleshooting Checklist
- Check for clogged fins on the heat exchanger and/or obstructions in the air passages.
- If no obstructions are found proceed to ohm the condenser fan motor. The compressor should also be ohmed out as well.
- If fan motor ohms within proper readings replace the Main Control board.
- If the Main Control board has already been replaced then replace the compressor, Main Control board, IPM and ACTPM boards.
- Also, verify line sets!