Daikin 17 Series RXB / RKB / FTKB Install/ Specs/ Service
print icon

Dakin 17 Series RXB/RKB 09-24k

 

 

 

 

 

 

BTUH Heat
Pump
Wall
Mounted
SEER EER HSPF COP Line Set Max Length
(Total/Vertical)
MOCP Cooling
(AHRI 95⁰ F)
Cooling
(Min/Max)
Heating
(AHRI 47⁰ F)
Heating
(Min/Max)
Heating
(AHRI 17⁰ F)
Heating
(5⁰ F DB/WB)
9,000 RXB09AXVJU FTXB09AXVJU 17.00 11.00 9.00 3.56 1/4" x 3/8" 66' / 33' 15 8,800 4,400/10,200 9,400 4,400/13,600 5,800 4,603
12,000 RXB12AXVJU FTXB12AXVJU 17.00 8.50 9.00 3.30 1/4" x 3/8" 66' / 33' 15 11,000 4,400/13,000 11,300 4,400/16,200 7,200 5,533
18,000 RXB18AXVJU FTXB18AXVJU 17.00 10.50 9.00 3.30 1/4" x 1/2" 98' / 33' 20 18,000 4,300/21,200 17,900 4,000/22,500 10,200 8,765
24,000 RXB24AXVJU FTXB24AXVJU 17.00 11.00 9.00 3.68 1/4" x 5/8" 98' / 33' 20 21,200 6,000/22,200 21,200 4,100/27,300 11,800 10,381
BTUH AC Only Wall
Mounted
SEER EER HSPF COP Line Set Max Length
(Total/Vertical)
MOCP Cooling
(AHRI 95⁰ F)
Cooling
(Min/Max)
 
9,000 RKB09AXVJU FTKB09AXVJU 17.00 11.00 - - 1/4" x 3/8" 66' / 33' 15 8,800 4,400/10,200 PHASING OUT CY23-Q1 thru CY23-Q3 ,
replaced by 18.2 SEER2 HP Only- Confirm Availability
12,000 RKB12AXVJU FTKB12AXVJU 17.00 8.50 - - 1/4" x 3/8" 66' / 33' 15 11,000 4,400/13,000
18,000 RKB18AXVJU FTKB18AXVJU 17.00 10.50 - - 1/4" x 1/2" 98' / 33' 20 18,000 4,300/21,200
24,000 RKB24AXVJU FTKB24AXVJU 17.00 11.00 - - 1/4" x 5/8" 98' / 33' 20 21,200 6,000/22,200

 

 

Features/Controls:

 

Optional Wired Controls: None

 

Optional Wi-Fi Controls: None

 

Low Ambient Operation:  None- No cooling operation below 50 degrees

 

Wind Baffle: Not Available

 

Condensate Lift Pumps: DACA-CP1-1 Aspen Mini Univolt Inline Pump / DACA-CP3-1 Sauermann Si30 Mini Inline Condensate Pump / DACA-CP4-1 Aspen Mini White (External) Univolt Pump Kit (or equal)

 

Installation (Wiring): Use 4-Wire, 14AWG, Stranded, Non-Shielded Wire to Connect Outdoor to Indoor. Only Break L1 for proper condensate pump wiring (breaking L3 will result in a U4 Error Code).

 

Installation (General): Mount outdoor units MINIMUM of 2" above anticipated snowfall. 

 

ALLOWED LINESET LENGTHS:

See Below

 

RKB / RXB ADDITIONAL CHARGE:

 

See Below

 

Daikin Torque Rating:

See below

 

Fault Codes:

 

FAULT DIAGNOSIS (For Inverter only)  
FAULT DIAGNOSIS BY REMOTE CONTROLLER
The temperature display sections indicate corresponding codes.
1.      When  the  ON TIMER  CANCEL button  or OFF TIMER  CANCEL button  is  held  down  for 5 seconds, a “” indication flashes on the temperature display section.
ON TIMER CANCEL                                                                              OFF TIMER CANCEL
2.      Press  the  ON  TIMER  CANCEL  button  or  OFF  TIMER  CANCEL  button  repeatedly  until  a continuous beep is produced.
•   The code indication changes as shown below, and notifies with a long beep.
ERROR CODE MEANING    
00 NORMAL    
A1 INDOOR PCB ERROR    
A3 DRAIN PUMP ABNORMAL    
A5 ANTIFREEZE (COOLING)/HEAT EXCHANGER OVERHEAT (HEATING)    
A6 INDOOR FAN MOTOR ABNORMAL    
AH ELECTRICAL AIR CLEANER ABNORMAL    
C4 INDOOR HEAT EXCHANGER (1) THERMISTOR SHORT/OPEN    
C5 INDOOR HEAT EXCHANGER (2) THERMISTOR SHORT/OPEN    
C7 LOUVER LIMIT SWITCH ERROR    
C9 INDOOR ROOM THERMISTOR SHORT/OPEN    
E1 OUTDOOR PCB ERROR    
E3 HIGH PRESSURE PROTECTION    
E4 LOW PRESSURE PROTECTION    
E5 COMPRESSOR MOTOR LOCK/COMPRESSOR OVERLOADED    
E6 COMPRESSOR START-UP ERROR    
E7 OUTDOOR DC FAN MOTOR LOCK    
E8 AC INPUT OVER CURRENT    
E9 EXV ERROR    
EA 4 WAY VALVE ERROR    
F3 DISCHARGE PIPE OVERHEAT    
F6 HEAT EXCHANGER OVERHEAT    
HO COMPRESSOR SENSOR SYSTEM ERROR    
H3 HIGH PRESSURE SWITCH ERROR    
H6 COMPRESSOR FEEDBACK DETECTION ERROR    
H7 FAN MOTOR OVERLOADED/OVERCURRENT/SENSOR ABNORMAL    
H8 AC CURRENT SENSOR ERROR    
ERROR CODE MEANING    
H9 OUTDOOR AIR THERMISTOR SHORT/OPEN    
J1 PRESSURE SENSOR ERROR    
J3 COMPRESSOR DISCHARGE PIPE THERMISTOR SHORT/OPEN/MISPLACED    
J5 SUCTION PIPE THERMISTOR SHORT/OPEN    
J6 OUTDOOR HEAT EXCHANGER THERMISTOR SHORT/OPEN    
J7 SUBCOOLING HEAT EXCHANGER THERMISTOR SHORT/OPEN    
J8 LIQUID PIPE THERMISTOR SHORT/OPEN    
J9 GAS PIPE THERMISTOR SHORT/OPEN    
L1 INVERTER OUTDOOR PCB ERROR    
L3 OUTDOOR CONTROL BOX OVERHEAT    
L4 HEAT SINK OVERHEAT    
L5 IPM ERROR/IGBT ERROR    
L8 INVERTER COMPRESSOR OVERCURRENT    
L9 COMPRESSOR OVERCURRENT PREVENTION    
LC COMMUNICATION ERROR (OUTDOOR CONTROL PCB AND INVERTER PCB)    
P1 OPEN PHASE OR VOLTAGE UNBALANCE    
P4 HEAT SINK THERMISTOR SHORT/OPEN    
PJ CAPACITY SETTING ERROR    
U0 INSUFFICIENT GAS    
U2 DC VOLTAGE OUT OF RANGE    
U4 COMMUNICATION ERROR    
U7 COMMUNICATION ERROR (OUTDOOR CONTROL PCB AND IPM PCB)    
UA INSTALLATION ERROR    
UF PIPING & WIRING INSTALLATION MISMATCH/WRONG WIRING/INSUFFICIENT GAS    
UH ANTIFREEZE (OTHER ROOMS)    
NOTE
1.  A short beep and two consecutive beeps indicate non-corresponding codes.
2.  To cancel the code display, hold the ON TIMER CANCEL button or OFF TIMER CANCEL button down for 5 seconds. The code display also cancel itself if the button is not pressed for 1 minute.
 

 

 

We are still looking for service manual. Call us if you need help.

 

 