Goodman GM9C / GC9C 2 Stage ECM Furnace Install/Spec/Service
print icon

Goodman 2 stage ecm furnaces will have board with a 3 digit display but this unit does not have the blue tooth capability. All setting to be done using the menus and push buttons to navigate.

 

These furnaces are setup from the factory to have  a 2 stage thermostat connected. If you are going to use single stage thermostat you must change this setting upon startup. 

 

NOTE: When setting up blower speeds for heat mode, GAf will be the menu item on single stage furnaces. While GA1 and GA2 will be menu items for two stage equipment.  

 

The code "IDL" or if you are reading board upside down,"7P1" is strictly saying that the furnace is idle with no call. This is not a fault code.

 

Models this article applies to:

GM9C960403BN

GM9C960603BN

GM9C960803BN

GM9C960804CN

GM9C961005CN

GM9C961205DN

GC9C960403BN

GC9C960603BN

GC9C960803BN

GC9C960804BN

GC9C961005CN

GC9C961205DN

 

See below for more information.

 

 

 