Date: May 6, 2025
Applies To: D5CUHA / D5CURA with ICP Fan Coils and Furnaces
Purpose: Improved performance and updated AHRI ratings for R-454B crossover systems.


πŸ”§ Why This Matters

Contractors reported that some R-454B crossover systems weren’t delivering expected efficiency. Carrier responded by improving the software inside the D5CUHA/D5CURA condensers, leading to better performance and more AHRI-certified combinations.


πŸ†• What’s New

βœ… Updated Compressor Algorithm

  • Boosts performance

  • Expands compatibility with more indoor units

βœ… New AHRI Ratings

  • Most system combinations now perform better

  • Ratings include an identifier: +TIC2025-0016

βœ… More Certified Combos

  • More fan coil and furnace matches are now officially rated


πŸ” Where to Look

When checking AHRI ratings, you may see two entries for the same outdoor model:

  1. Original rating

  2. New rating (with +TIC2025-0016)

Example:

  • D5CUHAH30AAK β†’ original rating

  • D5CUHAH30AAK +TIC2025-0016 β†’ new, higher performance


πŸ“ˆ Sample Rating Comparison (30k Model)

Combo SEER2 EER2 Htg. Capacity HSPF2 COP @ 5Β°F CCHP Ratio
Original 15.2 9.5 34,400 8.5 1.75 88%
New (+TIC2025-0016) 16.5 10 36,000 9.0 1.96 89%


πŸ›  How to Get the New Performance

1. Factory Upgrade

  • Same model number

  • New product number ends in -02
    e.g. D5CUHAH30AAK01 β†’ D5CUHAH30AAK02

2. Field Upgrade

  • Flash the board (tools provided)

  • Or replace the board during install

  • No rating plate change needed

  • Full instructions will come in the TIC by May 19


πŸ“… Timing & Rollout

  • Factory production with the updated board starts this month

  • Serial number cutoffs will be announced soon

  • TIC documentation available by May 19, 2025


βœ”οΈ Quick Recap

  • Equipment model number stays the same

  • New rating only applies with updated control board

  • Look for +TIC2025-0016 to confirm improved system

  • Use either factory-provided or field-installed upgrade path